Description
WANTY PTA Balloon Catheter yog ib qho hla cov hlau (OTW) peripheral balloon catheter, tshwj xeeb tsim los rau percutaneous transluminal angioplasty hauv atherosclerotic obstructed hlab ntsha.
Cov txheej hydrophilic uas npog qhov kawg ntawm lub catheter muab kev txhim kho lubricity rau lub balloon ncej.
A guidewire ({{0}}.014" 0.018" 0.035") is recommended for use with the Balloon Catheter (Balloon catheter specification refers to the attachment for detailed). The connector(s) at the end of hub provide two accuracy conical fittings with a 6 percent luer taper for securely fitted to other medicalequipment.
Intened use
WANTY PTA Balloon Catheters tau qhia rau peripheral transluminal angioplasty (PTA) rau peripheral vascular system (xws li cov hlab ntsha iliac, femoral artery, iliac femoral artery, popliteal artery thiab inferior genicular artery). xam txoj kab uas hla rau kev kho mob ntawm obstructive kab mob ntawm peripheral hlab ntsha.

Qauv Specifications
Recommended guidewire0.035", double lumen catheter | ||||||||||
Catheter length(cm) | Balloon diameter (mm) | Balloon Length(mm) | ||||||||
20 | 40 | 60 | 80 | 100 | 120 | 150 | 200 | 220 | ||
80 | 3.00 | H080030002035D | H080030004035D | H080030006035D | H080030008035D | H080030010035D | H080030012035D | H080030015035D | - | - |
3.50 | H080035002035D | H080035004035D | H080035006035D | H080035008035D | H080035010035D | H080035012035D | H080035015035D | - | - | |
4.00 | H080040002035D | H080040004035D | H080040006035D | H080040008035D | H080040010035D | H080040012035D | H080040015035D | H080040020035D | H080040022035D | |
5.00 | H080050002035D | H080050004035D | H080050006035D | H080050008035D | H080050010035D | H080050012035D | H080050015035D | H080050020035D | H080050022035D | |
6.00 | H080060002035D | H080060004035D | H080060006035D | H080060008035D | H080060010035D | H080060012035D | H080060015035D | H080060020035D | H080060022035D | |
7.00 | H080070002035D | H080070004035D | H080070006035D | H080070008035D | H080070010035D | H080070012035D | H080070015035D | H080070020035D | H080070022035D | |
8.00 | H080080002035D | H080080004035D | H080080006035D | H080080008035D | - | - | - | - | - | |
9.00 | H080090002035D | H080090004035D | H080090006035D | H080090008035D | - | - | - | - | - | |
10.00 | H080100002035D | H080100004035D | - | - | - | - | - | - | - | |
12.00 | H080120002035D | H080120004035D | - | - | - | - | - | - | - | |
130 | 3.00 | H130030002035D | H130030004035D | H130030006035D | H130030008035D | H130030010035D | H130030012035D | H130030015035D | - | - |
3.50 | H130035002035D | H130035004035D | H130035006035D | H130035008035D | H130035010035D | H130035012035D | H130035015035D | - | - | |
4.00 | H130040002035D | H130040004035D | H130040006035D | H130040008035D | H130040010035D | H130040012035D | H130040015035D | H130040020035D | H130040022035D | |
5.00 | H130050002035D | H130050004035D | H130050006035D | H130050008035D | H130050010035D | H130050012035D | H130050015035D | H130050020035D | H130050022035D | |
6.00 | H130060002035D | H130060004035D | H130060006035D | H130060008035D | H130060010035D | H130060012035D | H130060015035D | H130060020035D | H130060022035D | |
7.00 | H130070002035D | H130070004035D | H130070006035D | H130070008035D | H130070010035D | H130070012035D | H130070015035D | H130070020035D | H130070022035D | |
8.00 | H130080002035D | H130080004035D | H130080006035D | H130080008035D | - | - | - | - | - | |
9.00 | H130090002035D | H130090004035D | H130090006035D | H130090008035D | - | - | - | - | - | |
10.00 | H130100002035D | H130100004035D | - | - | - | - | - | - | - | |
12.00 | H130120002035D | H130120004035D | - | - | - | - | - | - | - | |
Hom qauv thiab specifications
Kab mob | PTA Balloon Catheter | Model Specifications |
Iliac artery stenosis | Common iliac artery:7-10mm; external iliac artery:5-8mm;Length: 40/60/80mm; Compatible guide wire: 0.035inch,Push rod length: 130cm; | ib: H130060008035 |
Femoropopliteal artery stenosis | Diameter 3-6mm; length 40-220mm; Compatible guide wire: {{0}}.035/0.018inch; push rod length: 130cm; | Piv txwv li: H130030015018,H130040015018 |
Inferior genicular artery stenosis | Diameter 1.5-4.0mm;conical balloon; length 20-220mm; Compatible guide wire:{{0}}.035/0.018inch; push rod length: 150/180cm; | Piv txwv li: H150020015014, H150025015014 |
central vein | Diameter: 6-12mm; Length: 40/60/80/100mm Compatible guide wire: 0.035inch; push rod length:130cm | Piv txwv li: H130100004035, H130120004035 |
TIPS | Txoj kab uas hla: 6/8mm; Ntev: 60/80mm Compatible guide wire:0.035inch;push rod length:80cm | ib: H080060008035 |
Product Advantage
Lub zais pa yog folded los ntawm kev sib cais thiab dov txheej txheem kom txo tau qhov folded cross -sectional cheeb tsam, lub zais pa rov zoo, thiab muaj kev nco
Barty koom tes nrog jMedtech los tsim cov txheej txheem hydrophilic txheej. Muab ob npaug rau- txheej txheej yog saws los txo thrombosis thiab txhim kho catheter passability

Tiv tauj xov xwm
Lub npe: Eiffel lu
Email: Lllu@batymedical.com
Txawb: ntxiv rau 86 182 2165 9426( whatsapp)
Cim npe nrov: wanty 0.035'' otw pta balloon dilatation catheter, China, suppliers, manufacturers, factory, customized, OEM